Deprecated: Return type of Requests_Cookie_Jar::offsetExists($key) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Cookie/Jar.php on line 63

Deprecated: Return type of Requests_Cookie_Jar::offsetGet($key) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Cookie/Jar.php on line 73

Deprecated: Return type of Requests_Cookie_Jar::offsetSet($key, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Cookie/Jar.php on line 89

Deprecated: Return type of Requests_Cookie_Jar::offsetUnset($key) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Cookie/Jar.php on line 102

Deprecated: Return type of Requests_Cookie_Jar::getIterator() should either be compatible with IteratorAggregate::getIterator(): Traversable, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Cookie/Jar.php on line 111

Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetExists($key) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 40

Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetGet($key) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 51

Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetSet($key, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 68

Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::offsetUnset($key) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 82

Deprecated: Return type of Requests_Utility_CaseInsensitiveDictionary::getIterator() should either be compatible with IteratorAggregate::getIterator(): Traversable, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home1/nyasham/renaissancendis.com.au/wp-includes/Requests/Utility/CaseInsensitiveDictionary.php on line 91
how to convert packed decimal to numeric in cobol
what does an industrial piercing say about you

how to convert packed decimal to numeric in cobol


Deprecated: Calling static trait method Neve\Customizer\Defaults\Layout::get_meta_default_data is deprecated, it should only be called on a class using the trait in /home1/nyasham/renaissancendis.com.au/wp-content/themes/neve/inc/views/post_layout.php on line 181

Deprecated: str_replace(): Passing null to parameter #3 ($subject) of type array|string is deprecated in /home1/nyasham/renaissancendis.com.au/wp-includes/formatting.php on line 4267
  • by

If doing it that way, you should check that the decimal point is a decimal point, and you should check that your numeric fields are numeric. In this tip, I will show you how to A job script may be created using a text editor. the hex number 0x48. decimal digits per byte in contrary of the Zoned number representation that holds This example illustrates the following functions. Creating and Using Files: Data Types and Data Storage the GnuCOBOL Technologies Refer to The compiler (cobc) translates COBOL source to executable using intermediate C, designated C compiler and linker. Each picture character represents one . the expense of increased code complexity. the COBOL Routine for Example-203 I HAVE A PACKED DECIMAL FIELD WHICH IS REDEFINED TO A NUMERIC FIELD TO ADD "1" TO ITS TENTH DIGIT. I am creating an SSIS package to read in unpacked data from a series of copybook files. I apologize for being thick-headed, but how can you expect to redefine a Packed-Decimal as floating-point? The mask for the Result field will cause an explicit decimal point to be inserted. FIELD-NAME-3 PIC S9(3)V9(6) COMP-3. and view the COBOL source code for this numeric field conversion example. Refer to CCURE 9000 AC9001 Installer/Maintainer Student Guide Appendix A 106. fPerformance Exam 1 (PE1) The scoring for Performance Exam 1 (PE1) is based on a three-part score. Styling contours by colour and by line thickness in QGIS, Equation alignment in aligned environment not working properly, Implement Seek on /dev/stdin file descriptor in Rust. For eg, WS-VAR S9 (3) COMP-3. Comp-3 is a common data type, even outside of COBOL, and is fairly standard across platforms -- that is, it is not . Caveat, this was just freehand, I haven't tried compiling it. A packed decimal representation stores decimal digits in each "nibble" of a byte. database using SORT - CONVERT PD to ZD and BI to ZD. I need to convert the values of packed decimal fields in itab to numeric type. available from SourceForge. the COBOL Routine for Example-304 2) Using the EDIT mask in the JCL. It consists of the word PIC or PICTURE followed by the actual picture clause, where the type and size are specified. This test case will show the process for converting a packed-numeric format to a display (or zoned-decimal) format. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon. The light-blue boxes identify the input/output data structures such as Documents, Spreadsheets, Data Files, VSAM Data Sets, Partitioned Data Set Members (PDSM's) or Relational Tables. will be occupying 2 bytes and the corresponding Easytrieve declaration is. Conversion of Packed Decimal to Numeric or zoned decimal? -IBM Mainframes COBOL Computational Fields: comp, comp-3, packed decimal, binary - A This document will focus on a discussion of a numeric field (or data string) known as "PACKED-DECIMAL" format (also referred to as packed data or a packed numeric field). SimoTime Technologies was founded in 1987 and is a privately owned company. At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. Why do many companies reject expired SSL certificates as bugs in bug bounties? Move LOW-VALUES to the first byte of the 2-bytes variable. FIELD-NAME-2 PIC S9(3)V9(8) COMP-3. My code is GPL licensed, can I issue a license to have my code be distributed in a specific MIT licensed project? 04 COBOL: Zoned Decimal and packed decimal - YouTube As Mainframe_help1 said you can redefine it. Help? 02 HORA-OUT PIC X(6). The function delivered in this version is based upon the enhancement requests from a specific group of users. Making statements based on opinion; back them up with references or personal experience. This test case will show the process for converting a binary numeric format to a display (or zoned-decimal) format. 02 FIELD1-NUM PIC 9(06)V99. As said above, UNSTRINGing and combining didnt work, but REDEFINES works! the COBOL Routine for Example-103 I need to convert the values of packed decimal fields in itab to numeric type. PD: Input format in Packed Decimal TO=ZDF: output format to be in all numerics TO=ZD: output format to be in all numerics with an alphabet LENGTH=n: If you want to override the output length, specify as n. Example. Then I have the script component output parameter set to DT_NUMERIC with a precision of 7 and scale of 2. The only difference is that my mainframe file has one packed field that looks like:1469, 300CI have the File connection manager set to DT_BYTES with an output column width of 4. Use the language as it was intended to be used. Explore the COBOL Connection for more examples of COBOL programming techniques and sample code. Data type conversion from packed to numeric | SAP Community How to use Slater Type Orbitals as a basis functions in matrix method correctly? Packed Decimal. The following (NBRCVTE1.cmd) is a sample of the Windows CMD needed to run this job in a non-Mainframe environment. In case of the above question to move the decimal portion of the number need to define an variable which can store only the decimal portion and move the value to that field which would hold just the decimal portion. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. Refer to the are String with a length of 50. A variety of numeric formats are used on an IBM Mainframe System, a Windows System, a UNIX System or a Linux System. The following is an example of actual COBOL source code. Asusually, I could find out a way to achieve it! Moving packed-decimal (PIC S9(11)V99 COMP-3) to zoned-decimal (PIC S9(11)V99) is completely valid - providing the comp-3 data is properly signed numeric. 02 IMPME-OUT PIC S9(13)V9(2) COMP-3. 02 CONVAL1-OUT PIC S9(13)V9(2) COMP-3. Software Agreement and Disclaimer. The hexadecimal information is (highlighted in green) The possible translated, displayable EBCDIC characters are (highlighted in blue). How do you convert a packable decimal to a readable format? Script Component has encountered an exception in user code : Project name: SC_502c8f1c0d6b40d7929990353c01db83, at System.Data.SqlTypes.SqlDecimal.ConvertToPrecScale(SqlDecimal n, Int32 precision, Int32 scale), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.SetDecimal(Int32 columnIndex, Decimal value), at Microsoft.SqlServer.Dts.Pipeline.PipelineBuffer.set_Item(Int32 columnIndex, Object value), at Microsoft.SqlServer.Dts.Pipeline.ScriptBuffer.set_Item(Int32 ColumnIndex, Object value), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.ScriptMain.Input0_ProcessInputRow(Input0Buffer Row), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.Input0_ProcessInput(Input0Buffer Buffer), at SC_502c8f1c0d6b40d7929990353c01db83.vbproj.UserComponent.ProcessInput(Int32 InputID, PipelineBuffer Buffer), at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer buffer). This suite of programs is provided as a COBOL example of one of the possible solutions to the problem of determining the actual format, content and length of a numeric field and converting to a different format. public inbox for gccadmin@sourceware.org help / color / mirror / Atom feed * Cron <gccadmin@sourceware> sh /home/gccadmin/scripts/update_web_docs_svn @ 2018-08-07 0: . The following (NBRCVTJ1.jcl) is a sample of the ZOS oriented JCL needed to run this job in a Mainframe-oriented environment. data we cant handle its content as simple text anymore, we need to perform analysis The actual representation which we want is: To achieve this, the SYSIN of SORT should be: Drop a comment below if you face any problem using the above example. Spaces also are pretty good at "disguising" themselves as "zoned"/"display" numerics (zeros), it is on when they get in the "sign" left-most "half" of the right-most byte that they "might" (depending on other things) cause a S0C7. This can be accomplished using SORT. 02 CAUSAL-OUT PIC X(3). The Result Field is defined as a Display field with 5 digits and zero decimal positions. Your email address will not be published. Packed numbers are amongst the hardest data sets to import into a SQL Server COBOL Comp-3 / Packed-decimal - www.www.mainframestechhelp.com Redefine the 2-byte alphanumeric variable as PIC S9 (04) COMP. If you are running in CICS, you could use the BIF DEEDIT function -- that will leave you with "00.450". This test case will show the process for converting a zoned-decimal-numeric format to a display format. How do I convert comp to numeric in Cobol? - Stwnews.org 02 TETI-OUT PIC X(4). Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. The fewer decimal positions of the result field will cause the numeric value to be truncated. To I am very glad that these tipshad helped you! This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause. ** The 'V' is an implied decimal point. and view the COBOL source code for this numeric field conversion example. 18 digits requires 9 bytes, the sign is the low nybble of the low order byte. The lower nibble of the last byte has 13 if the number is negative, and something else, (usually 12) if positive. Therefore, when the field is used in the calculation specifications, the result field must be nine positions long. Also The following PROCEDURE DIVISION statement shows how to convert from a ZONED-DECIMAL to a DISPLAY (with SIGN TRAILING SEPARATE) numeric value. The following shows the picture (PIC) clause, how the item is displayed using the DISPLAY verb, the field as it is stored in memory for an EBCDIC environment, the field as it would be stored in memory for an ASCII environment. Is there an existing gem or script that converts numbers to comp-3/packed decimal format? REFFILE. Rarely (if ever) is packed-decimal business data moved to a floating-point field. Radial axis transformation in polar kernel density estimate. You can download the SSIS package and the sample text file used for this I am unsure of the correct interpretation of the following field definitions and was hoping someone would know: FIELD-NAME-1 PIC S9(15)V9(3) COMP-3. Is it possible to rotate a window 90 degrees if it has the same length and width? We have to instruct Given that your input field length is 11, what output would you expect for an input like this? The fewer decimal positions of the result field will be rounded because of the ROUNDED keyword on the ADD statement. The following is the WORKING-STORAGE definition for the source field. This can be accomplished using SORT. bPacked (Byte Array): A byte array containing the packed number to be converted to decimal format. 359 , Road No. This test case will show the process for converting a packed-numeric format to a display (or zoned-decimal) format. do so, just right click on the Flat File Source and select Show Advanced Editor representation. Explore The Zoned-Decimal format for numeric data strings. It's simply. When you write a packed field to a WORK file, the output record will contain the field in packed format. That is a File Master 3.11 Reformat example: ------------------ CA File Master Plus -- Dataset Reformat ------------------. This example also illustrates how to display the actual hexadecimal (or Hex Dump) content of a numeric field using a callable dump routine. On the Script Tab select Visual Basic as the Script Language. The Source Field is defined as a Packed (or COMP-3) field with 6 digits and 3 decimal positions. . it doesn't exist on the file, but COBOL knows that it's there for rounding and such. The following is the mainframe JCL required to run the jobs in a ZOS oriented, Mainframe environment. See method getMainframePackedDecimal in http://jrecord.cvs.sourceforge.net/viewvc/jrecord/jrecord/src/net/sf/JRecord/Common/Conversion.java?revision=1.2&view=markup, for an example of converting packed decimal in java (it is part of the jrecord project jrecord.sf.net). able to handle this field as a string. i have a packed decimal field which is redefined to a numeric field to add "1" to its tenth digit. Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. Explore How to do EBC to ASC Data Conversion of an 80 byte Data Structure. Converting numbers. - Ask TOM - Oracle A string containing the converted string. The sign indication is dependent on your operating environment. 01 WS-NUMERIC-EDIT PIC 99,999,999.99. No exact equivalent. Can we move alphanumeric to numeric in cobol? If an item declared as COMP-3, the item appears in storage in packed decimal format. Converting alphanumeric field to numeric - COBOL General discussion If the packed decimal is 0x11234D. Morevoer i got SOC7 abend. NULL value, which is used as the string terminator. Move packed field to X (05) (here I got value as x'0123450000') Converting packed to string:-. One copybook for the source data structure and one for the new data structure.For example: 01 DATAREC1OLD. COMP-3 data stored in memory higher to lower in the size of nibble (4 bits). The actual number of bytes occupied in the file is about half of that bytes. Enter 2 and 3 in the TO section of the panel, for example: CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT), ------------------------------------------------------------------------------. How to convert packed decimal values to numeric values via File Master using COBOL copybooksThis document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks.The only method to get this done is to use a File Master Reformat data set, aka. IF THERE IS ANY OTHER METHOD TO ADD ONE TO THE 1OTH DIGIT OF VALUE IN A PACKED DECIMAL FIELD WITHOUT CONVERTING IT INTO NUMERIC. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. Atlast divide the decimal-total by 1000 and add it to integer-part. Handling the case of the 10th digit being 9 is a trivial IF statement. To subscribe to this RSS feed, copy and paste this URL into your RSS reader. Integration I added a brief description 15 would stored as 01 5C. By clicking Accept all cookies, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy. I HAVE A PACKED DECIMAL FIELD WHICH IS REDEFINED TO A NUMERIC FIELD TO ADD "1" TO ITS TENTH DIGIT. This following three (3) COBOL programs show the level of detail required to convert a numeric field. The Result Field is defined as a Display field with 7 digits and 2 decimal positions. Is it possible to create a concave light? copybooks. ispf programmer s guide Full Book - bookforread.com Explore > (somehow) to the decimal value 168. A suitable definition for a table to load this file is next. The COBOL USAGE clause would be COMP, COMP-3 and DISPLAY. SSIS documentation about Data Types for the DT_STR type, you will see that Integration And Please suggest any other way to achieve the same! Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? I think the problem are in this columns : Actually Im usingbyte stream [DT_BYTES] format in flat file source andnumeric [DT_NUMERIC] in script component. if itab-menge has a value of 2.00, i need to convert that value to ' 200'. The nature of simulating nature: A Q&A with IBM Quantum researcher Dr. Jamie We've added a "Necessary cookies only" option to the cookie consent popup. grapple attachment for kubota tractor Monday-Friday: 9am to 5pm; Satuday: 10ap to 2pm suburban house crossword clue Regd. I assume the format is not fixed, since then you could just pick that part of the string and move it to a field defined with pic 9.999 and use it from there. the COBOL Routine for Example-101 Using V6.2 and ARCH(12), the compiler instead uses the vector packed-decimal facility, which accelerates packed and zoned decimal computation by storing intermediate results in vector registers instead . i have a question on data type conversion. Length specified in Easytrieve always specifies the number of bytes occupied and not number of digits. Can Martian regolith be easily melted with microwaves? Why do we calculate the second half of frequencies in DFT? If the spaces were not there, the ABCDEF would not give you a problem, but would not give you the results you expect as the would be erroneously interpreted as digits. This allowed programmers to economize space by using half of the size for numerical Conversion of NUMERIC field to PACKED DECIMAL -IBM Mainframes SORT - CONVERT PD to ZD and BI to ZD | F1 for Mainframe Would the magnetic fields of double-planets clash? can be converted to numeric values via File Master using COBOL copybooks. The purpose of this document is to assist a reader in developing a better understanding of the various numeric formats that are supported by an IBM Mainframe System. rev2023.3.3.43278. Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers. A suite of Bash Script Files is provided to run the jobs on a Linux or UNIX System with GnuCOBOL (formerly known as Open COBOL) being used to compile and execute the COBOL Programs. Disconnect between goals and daily tasksIs it me, or the industry? After dropping the Script Component a window will pop up Why are Suriname, Belize, and Guinea-Bissau classified as "Small Island Developing States"? For example, the value 15 is stored in two nibbles, using the hexadecimal characters 1 and 5. Disconnect between goals and daily tasksIs it me, or the industry? Neal, It was explicitly mentioned that "i need to get '0.450' as numeric decimal and do arithmetic on it.". With this you should be answered. So an 7 digit numeric number would require 7 +1 = 8 / 2 = 4 byte in size. We are going to instruct the SSIS pipeline Batch split images vertically in half, sequentially numbering the output files, Follow Up: struct sockaddr storage initialization by network format-string. Explore The Packed-Decimal or COMP-3 format for numeric data strings. This document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks. Right justified. Working with Packed Decimal and Zoned Decimal Data The next step is to set up the Inputs and Outputs tab. Numeric formats quite often require a conversion to another numeric format or data type prior to being printed, displayed or exported to a non-mainframe or non-COBOL environment. Other uses will require a SimoTime Software License. It is implemented as "comp-3". the COBOL Routine for Example-301 The Source Field is defined as a Binary (or COMP) field with 6 digits and 3 decimal positions. This group of test cases will show the process for converting a packed-numeric format (COMPUTATIONAL-3 or COMP-3) to a text string or display format. Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. Do we have a way? comp has different types of ways of storing the in my computer, IBM MAINFRAME, comp is binary and comp3 is packed decimal. This is an EBCDIC encoded environment. Since we are going to perform Copyright 1987-2023SimoTime Technologies and ServicesAll Rights Reserved. Notice that the second byte is a binary zero, also known as a We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms. How do you convert decimal to numeric in COBOL? Explore The File Status Return Codes to interpret the results of accessing VSAM data sets and/or QSAM files. Sorry I am two years late :-( . To convert from zoned to packed. To calculate the number of bytes, we have to add 1 (for sign) to the total number of digits, then need to divide it by 2, and round up. Does ZnSO4 + H2 at high pressure reverses to Zn + H2SO4? We reserve the right to make changes without notice at any time. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. and select {CR}{LF} as the row delimiter like on the next image. Moved '12345 ' to numeric field 9 (09) move numeric field 9 (09) to packed field S9 (10) COMP-3. I tried with below logic. Author: Franz Lanz Publisher: Walter de Gruyter GmbH & Co KG ISBN: 3110407612 Size: 74.53 MB Format: PDF, Docs View: 5532 Get Book Disclaimer: This site does not store any files on its server.We only index and link to content provided by other sites. What you probably need to do is something along the lines of: Yes, the above program uses an additional variable in the middle to convert numeric format to display format, but that is exactly how the language was designed. This link will require an Internet Connection. The following (NBRCVTJ3.jcl) is a sample of the ZOS oriented JCL needed to run this job in a Mainframe-oriented environment. A simple job script may contain a single job step that performs a single function. asking us how we want to use this Script Component. By default, a 4-byte BI value produces a 7-byte ZD value, but LENGTH=6 override the default length . 02 MONEDA-OUT PIC X(2). Site design / logo 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA. The status of each job step may be tested at the end of each job step. The zone and numeric digit of the rightmost byte of the zoned decimal number are reversed and placed in the . As said above, UNSTRINGing and combining didnt work, but REDEFINES works! Packed decimal conversion packed field = packed field * 10. What is the significance of the code at right of variable declaration in COBOL? This first patch isn't directly applicable to all the projects, but if this is approved then I have follow-on patches for gdb and binutils. The following is a flowchart of the job for executing the programs that show the conversion between the various numeric field types. Convert Packed decimal to Numeric -IBM Mainframes You can't define your field decimals like that and use it in a COMPUTE. This suite of test cases describes how to convert between the various numeric formats (or data types such as DISPLAY, COMP, COMP-3 or DECIMAL, BINARY and PACKED) used with COBOL and on an IBM Mainframe System. To learn more, see our tips on writing great answers. The sign indication is dependent on your operating environment. Browse other questions tagged, Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide. The three most common mainframe numeric encoding formats are Zoned-Decimal, Packed-Decimal and Binary. PIC S9(15)V9(3) COMP-3 looks like this in the file: If the value was -4568248.323, it would be: This doesn't help you, but may help others. I've copied this code and setup my package identical to these instructions. For the Category and Balance fields a transformation we check the Transformation radio button and click the OK button. How to convert packed decimal values to numeric values via File Master using COBOL copybooks This document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks.The only method to get this done is to use a File Master Reformat data set, aka. and view the COBOL source code for this numeric field conversion example. 02 AGE-OUT PIC X(3).

Outlaw Mc Clubs Australia, Articles H

how to convert packed decimal to numeric in cobol